waterheaterspecs

Gas tankless water heaters

The gas tankless group holds 367 certified model numbers in 40 rating sets, from 23 brands. The highest max flow on the list, 6.0 gal/min at a 67 °F rise, belongs to A. O. Smith ATM-199M-N 1 and Vesta VTP-199. The largest rating set here, A. O. Smith ACT-199O-N 1, covers 51 model numbers sold as A. O. Smith, American, Lochinvar, Reliance, State and Takagi. One ENERGY STAR partner, A.O. Smith Corporation, lists 56% of the group’s model numbers.

Certified models as of October 27, 2026 · Open this type in the Heater finder

Max flow against gas input

Gas tankless sets

Max flow at a 67 °F rise, gal/min

Max flow against gas input3.54.04.55.05.56.06.5120130140150160170180190200Gas input, thousand Btu/hA. O. Smith ACT-199O-N 1A. O. Smith ATI-340H 1A. O. Smith ATHR-160M 1Rheem ECOHS200INA. O. Smith ATO-240H 1Rheem ECOHS160INRheem ECOHS180INA. O. Smith ATM-199M-N 1A. O. Smith ATHR-180M 1A. O. Smith ATHR-199M 1Bradford White RTGR150N1Midea JSG52-32PCH-LPA. O. Smith ATM-140M-N 1Midea JSG48-29PCH-LPBosch T9800 SE 199Noritz EZ111DV (GQ-C3261WX-FF US)Bosch T9800 SE 160Midea MGWH150IXNNRinnai (CX160I) REU-NB2530FFC-USRinnai (CX199I) REU-NB3237FFC-USKepler JSG52-32PCH/199KNPNoritz EZ111DV (GQ-C3260WX-FF US)Noritz EZ98DV (GQ-C2861WX-FF US)Midea JSG40-24PCH-LPNavien NPE-180A2Noritz EZ71DV (GQ-C2661WX-FF US)Noritz NRCR92DV (GQ-C2661WXQ-FF US)Vesta VRS PLUS-199Kepler JSG48-29PCH/180KNavien NPE-180S2Navien NPE-210A2Navien NPE-210S2Navien NPE-240A2Noritz EZ98DV (GQ-C2860WX-FF US)Noritz NRCR92DV (GQ-C2660WXQ-FF US)Rinnai (RX130I) REU-NB2024FF-USVesta VRP-PLUS-150Vesta VTP-150Vesta VTP-199Vesta VTS-150
Max flow against gas input3.54.04.55.05.56.06.5120140160180200Gas input, thousand Btu/hA. O. Smith ACT-199O-N 1A. O. Smith ATI-340H 1A. O. Smith ATHR-160M 1Rheem ECOHS200INA. O. Smith ATO-240H 1Rheem ECOHS160INRheem ECOHS180INA. O. Smith ATM-199M-N 1A. O. Smith ATHR-180M 1A. O. Smith ATHR-199M 1Bradford White RTGR150N1Midea JSG52-32PCH-LPA. O. Smith ATM-140M-N 1Midea JSG48-29PCH-LPBosch T9800 SE 199Noritz EZ111DV (GQ-C3261WX-FF US)Bosch T9800 SE 160Midea MGWH150IXNNRinnai (CX160I) REU-NB2530FFC-USRinnai (CX199I) REU-NB3237FFC-USKepler JSG52-32PCH/199KNPNoritz EZ111DV (GQ-C3260WX-FF US)Noritz EZ98DV (GQ-C2861WX-FF US)Midea JSG40-24PCH-LPNavien NPE-180A2Noritz EZ71DV (GQ-C2661WX-FF US)Noritz NRCR92DV (GQ-C2661WXQ-FF US)Vesta VRS PLUS-199Kepler JSG48-29PCH/180KNavien NPE-180S2Navien NPE-210A2Navien NPE-210S2Navien NPE-240A2Noritz EZ98DV (GQ-C2860WX-FF US)Noritz NRCR92DV (GQ-C2660WXQ-FF US)Rinnai (RX130I) REU-NB2024FF-USVesta VRP-PLUS-150Vesta VTP-150Vesta VTP-199Vesta VTS-150
Each circle is one rating set, sized by model numbers. Dashed line: input ÷ (8.34 × 60 × 67), the flow at which all of the gas input would go into a 67 °F rise. The test tolerances on inlet and outlet temperature let a few listings sit slightly above it.

Every rating set

Grouped by maximum gas input.

Gas tankless rating sets by gas input
Rating setMax flow, 67 °F riseGas inputUEF, drawGas useFuel
199,000 Btu/h13 sets
Vesta VTP-199
Show 1 model number
  • Vesta VTP-199
6.0 gal/min199,000 Btu/h0.96 high176 therms/yrnatural gas or propane
A. O. Smith ATM-199M-N 1Also listed as American, Lochinvar, Reliance, State
Show 14 model numbers
  • A. O. Smith ATM-199M-N 1**, ATM-199X3-N 1**, GT15TM-199M-N, GT15TM-199M-N 1**, GT15TM-199X3-N, GT15TM-199X3-N 1**
  • American MTM-199M-N 1**, MTM-199X3-N 1**
  • Lochinvar LTM-199M-N 1**, LTM-199X3-N 1**
  • Reliance RTM-199M-N 1**, RTM-199X3-N 1**
  • State STM-199M-N 1**, STM-199X3-N 1**
6.0 gal/min199,000 Btu/h0.95 high178 therms/yrnatural gas only
Vesta VRS PLUS-199
Show 2 model numbers
  • Vesta VRS PLUS-199, VTS-199
5.9 gal/min199,000 Btu/h0.96 high176 therms/yrnatural gas or propane
A. O. Smith ATHR-199M 1Also listed as American, Lochinvar, Reliance, State
Show 12 model numbers
  • A. O. Smith ATHR-199M 1**, ATHR-199X3 1**, GT15THR-199M 1**, GT15THR-199X3 1**
  • American MTHR-199M 1**, MTHR-199X3 1**
  • Lochinvar LTHR-199M 1**, LTHR-199X3 1**
  • Reliance RTHR-199M 1**, RTHR-199X3 1**
  • State STHR-199M 1**, STHR-199X3 1**
5.9 gal/min199,000 Btu/h0.95 high178 therms/yrnatural gas or propane
Rinnai (CX199I) REU-NB3237FFC-US
Show 4 model numbers
  • Rinnai (CX199I) REU-NB3237FFC-US, (CXP199I) REU-NBP3237FFC-US, (RX199I) REU-NB3237FF-US, (RXP199I) REU-NBP3237FF-US
5.8 gal/min199,000 Btu/h0.98 high173 therms/yrnatural gas or propane
Rheem ECOHS200INAlso listed as Bradford White, Friedrich, Kiturami, Laars, Navien, Richmond, Ruud
Show 35 model numbers
  • Bradford White RTGR199N1**, RTGR199X1**, RTGS199N1**, RTGS199X1**
  • Friedrich FDTGH-S11I, FDTGH-SR11I
  • Kiturami KGWH-190JFN, KGWH-190JFP, KGWH-199JFRN, KGWH-199JFRP
  • Laars LT199NRX1**, LT199NXX1**, LT199PRX1**, LT199PXX1**
  • Navien NPE-240S2
  • Rheem ECOHS200IN, ECOHS200IP, ECOHSR200IN, ECOHSR200IP, RECTGH-S11IN, RECTGH-S11IP, RECTGH-SR11IN, RECTGH-SR11IP, RTGH-CS11I, RTGH-CSR11I, RTGH-S11I, RTGH-SR11I
  • Richmond RMTGHS11IN, RMTGHS11IP, RMTGHSR11IN, RMTGHSR11IP
  • Ruud RUTGH-CS11I, RUTGH-CSR11I, RUTGH-S11I, RUTGH-SR11I
5.8 gal/min199,000 Btu/h0.96 high176 therms/yrnatural gas or propane
A. O. Smith ACT-199O-N 1Also listed as American, Lochinvar, Reliance, State, Takagi
Show 51 model numbers
  • A. O. Smith ACT-199O-N 1**, ACT-199O-P 1*1, ACTH-199M-(N,P) 1**, ATO-540H 1**, ATO-540H 1*1, ATO-540HX3-N 1**, ATO-540HX3-P 1*1, ATO-540P-N 1**, ATO-540P-P 1*1, GT15-540-NO 1**
  • American GT-540-NEH 1**, GT-540-PEH 1*1, GT-540P-NEH 1**, GT-540P-PEH 1*1, GT-540X3-NEH 1**, GT-540X3-PEH 1*1, MCT-199O-N 1**, MCT-199O-P 1*1, MCTH-199M-(N,P) 1**
  • Lochinvar LCT-199O-N 1**, LCT-199O-P 1*1, LCTH-199M-(N,P) 1**, LTO-540H-N 1**, LTO-540H-P 1*1, LTO-540HX3-N 1**, LTO-540HX3-P 1*1, LTO-540P-N 1**, LTO-540P-P 1*1
  • Reliance TS-540-GEH 1**, TS-540-LEH 1*1, TS-540P-GEH 1**, TS-540P-LEH 1*1, TS-540X3-GEH 1**, TS-540X3-LEH 1*1
  • State GTS-540-NEH 1**, GTS-540-PEH 1*1, GTS-540P-NEH 1**, GTS-540P-PEH 1*1, GTS-540X3-NEH 1**, GTS-540X3-PEH 1*1, SCT-199O-N 1**, SCT-199O-P 1*1, SCTH-199M-(N,P) 1**
  • Takagi T-H3-OS-N 1**, T-H3-OS-P 1*1, TCT-199O-N 1**, TCT-199O-P 1*1, TK-540P-NEH 1**, TK-540P-PEH 1*1, TK-540X3-NEH 1**, TK-540X3-PEH 1*1
5.8 gal/min199,000 Btu/h0.95 high178 therms/yrnatural gas or propane
Kepler JSG52-32PCH/199KNPAlso listed as Kings Peak
Show 3 model numbers
  • Kepler JSG52-32PCH/199KNP, JSG52-32PCH/199KWP
  • Kings Peak KNG199ICW
5.7 gal/min199,000 Btu/h0.96 high175 therms/yrnatural gas only
Midea JSG52-32PCH-LPAlso listed as MRCOOL, stream33
Show 12 model numbers
  • MRCOOL MHWH199NCLU, MHWH199NCNU
  • Midea JSG52-32PCH-LP, JSG52-32PCH-NG, JSG52-32PCHP-LP, JSG52-32PCHP-NG, MGWH199IXNN, MGWH199IXNP, MGWH199IXPN, MGWH199IXPP
  • stream33 S33-95TWH199-LP/NG, S33-95TWH199P-LP/NG
5.7 gal/min199,000 Btu/h0.95 high175 therms/yrnatural gas or propane
Noritz EZ111DV (GQ-C3260WX-FF US)
Show 3 model numbers
  • Noritz EZ111DV (GQ-C3260WX-FF US), NCC199CDV (GQ-C3260WZ-FF US), NRCR111DV (GQ-C3260WXQ-FF US)
5.6 gal/min199,000 Btu/h0.96 high176 therms/yrnatural gas or propane
Navien NPE-240A2
Show 1 model number
  • Navien NPE-240A2
5.6 gal/min199,000 Btu/h0.95 high178 therms/yrnatural gas or propane
Noritz EZ111DV (GQ-C3261WX-FF US)
Show 6 model numbers
  • Noritz EZ111DV (GQ-C3261WX-FF US), EZ111DV (GQ-C3261WX-FF-1 US), NCC199CDV (GQ-C3261WZ-FF US), NCC199CDV (GQ-C3261WZ-FF-1 US), NRCR111DV (GQ-C3261WXQ-FF US), NRCR111DV(GQ-C3261WXQ-FF-1 US)
5.5 gal/min199,000 Btu/h0.98 high173 therms/yrnatural gas or propane
Bosch T9800 SE 199Also listed as Bradford White
Show 6 model numbers
  • Bosch T9800 SE 199, T9800 SEO 199, T9900 SE 199
  • Bradford White RTG-K-199N1, RTG-K-199N2, RTGL 199N1
5.4 gal/min199,000 Btu/h0.95 high178 therms/yrnatural gas or propane
170,000 to 189,000 Btu/h9 sets
Noritz EZ98DV (GQ-C2860WX-FF US)
Show 1 model number
  • Noritz EZ98DV (GQ-C2860WX-FF US)
5.6 gal/min180,000 Btu/h0.96 high176 therms/yrnatural gas or propane
A. O. Smith ATI-340H 1Also listed as American, Lochinvar, Reliance, State, Takagi
Show 40 model numbers
  • A. O. Smith ATI-340H 1**, ATI-340H 1*1, ATI-340HX3-N 1**, ATI-340HX3-P 1*1, ATM-180M-N 1**, ATM-180X3-N 1**, GT15-340-NI 1**, GT15-340-PI 1*1, GT15TM-180M-N, GT15TM-180M-N 1**, GT15TM-180X3-N, GT15TM-180X3-N 1**
  • American GT-340-NIH 1**, GT-340-PIH 1*1, GT-340X3-NIH 1**, GT-340X3-PIH 1*1, MTM-180M-N 1**, MTM-180X3-N 1**
  • Lochinvar LTI-340H-N 1**, LTI-340H-P 1*1, LTI-340X3-N 1**, LTI-340X3-P 1*1, LTM-180M-N 1**, LTM-180X3-N 1**
  • Reliance RTM-180M-N 1**, RTM-180X3-N 1**, TS-340-GIH 1**, TS-340-LIH 1*1, TS-340X3-GIH 1**, TS-340X3-LIH 1*1
  • State GTS-340-NIH 1**, GTS-340-PIH 1*1, GTS-340X3-NIH 1**, GTS-340X3-PIH 1*1, STM-180M-N 1**, STM-180X3-N 1**
  • Takagi T-H3S-DV-N 1**, T-H3S-DV-P 1*1, TK-340X3-NIH 1**, TK-340X3-PIH 1*1
5.4 gal/min180,000 Btu/h0.95 high178 therms/yrnatural gas or propane
Noritz EZ98DV (GQ-C2861WX-FF US)Also listed as Rinnai
Show 3 model numbers
  • Noritz EZ98DV (GQ-C2861WX-FF US), EZ98DV (GQ-C2861WX-FF-1 US)
  • Rinnai (RX180I) REU-NB2934FF-US
5.3 gal/min180,000 Btu/h0.98 high173 therms/yrnatural gas or propane
Navien NPE-210S2
Show 1 model number
  • Navien NPE-210S2
5.3 gal/min180,000 Btu/h0.96 high176 therms/yrnatural gas or propane
A. O. Smith ATHR-180M 1Also listed as American, Lochinvar, Reliance, State
Show 12 model numbers
  • A. O. Smith ATHR-180M 1**, ATHR-180X3 1**, GT15THR-180M 1**, GT15THR-180X3 1**
  • American MTHR-180M 1**, MTHR-180X3 1**
  • Lochinvar LTHR-180M 1**, LTHR-180X3 1**
  • Reliance RTHR-180M 1**, RTHR-180X3 1**
  • State STHR-180M 1**, STHR-180X3 1**
5.3 gal/min180,000 Btu/h0.95 high178 therms/yrnatural gas or propane
Kepler JSG48-29PCH/180K
Show 1 model number
  • Kepler JSG48-29PCH/180K
5.2 gal/min180,000 Btu/h0.96 high175 therms/yrnatural gas only
Rheem ECOHS180INAlso listed as Friedrich, Richmond, Ruud
Show 18 model numbers
  • Friedrich FDTGH-S10I, FDTGH-SR10I
  • Rheem ECOHS180IN, ECOHS180IP, ECOHSR180IN, ECOHSR180IP, RECTGH-S10IN, RECTGH-S10IP, RECTGH-SR10IN, RECTGH-SR10IP, RTGH-S10I, RTGH-SR10I
  • Richmond RMTGHS10IN, RMTGHS10IP, RMTGHSR10IN, RMTGHSR10IP
  • Ruud RUTGH-S10I, RUTGH-SR10I
5.2 gal/min180,000 Btu/h0.96 high176 therms/yrnatural gas or propane
Midea JSG48-29PCH-LP
Show 8 model numbers
  • Midea JSG48-29PCH-LP, JSG48-29PCH-NG, JSG48-29PCHP-LP, JSG48-29PCHP-NG, MGWH180IXNN, MGWH180IXNP, MGWH180IXPN, MGWH180IXPP
5.2 gal/min180,000 Btu/h0.95 high175 therms/yrnatural gas or propane
Navien NPE-210A2
Show 1 model number
  • Navien NPE-210A2
5.0 gal/min180,000 Btu/h0.95 high178 therms/yrnatural gas or propane
160,000 to 169,000 Btu/h7 sets
Noritz NRCR92DV (GQ-C2660WXQ-FF US)
Show 1 model number
  • Noritz NRCR92DV (GQ-C2660WXQ-FF US)
4.9 gal/min165,000 Btu/h0.95 high178 therms/yrnatural gas or propane
A. O. Smith ATHR-160M 1Also listed as American, Lochinvar, Reliance, State
Show 38 model numbers
  • A. O. Smith ATHR-160M 1**, ATHR-160X3 1**, ATM-160M-N 1**, ATM-160M-P 1*1, ATM-160X3-N 1**, ATM-160X3-P 1*1, GT15THR-160M 1**, GT15THR-160X3 1**, GT15TM-160M-N, GT15TM-160M-N 1**, GT15TM-160M-P 1*1, GT15TM-160X3-N, GT15TM-160X3-N 1**, GT15TM-160X3-P 1*1
  • American MTHR-160M 1**, MTHR-160X3 1**, MTM-160M-N 1**, MTM-160M-P 1*1, MTM-160X3-N 1**, MTM-160X3-P 1*1
  • Lochinvar LTHR-160M 1**, LTHR-160X3 1**, LTM-160M-N 1**, LTM-160M-P 1*1, LTM-160X3-N 1**, LTM-160X3-P 1*1
  • Reliance RTHR-160M 1**, RTHR-160X3 1**, RTM-160M-N 1**, RTM-160M-P 1*1, RTM-160X3-N 1**, RTM-160X3-P 1*1
  • State STHR-160M 1**, STHR-160X3 1**, STM-160M-N 1**, STM-160M-P 1*1, STM-160X3-N 1**, STM-160X3-P 1*1
4.8 gal/min160,000 Btu/h0.95 high178 therms/yrnatural gas or propane
Noritz EZ71DV (GQ-C2661WX-FF US)
Show 2 model numbers
  • Noritz EZ71DV (GQ-C2661WX-FF US), EZ71DV (GQ-C2661WX-FF-1 US)
4.7 gal/min160,000 Btu/h0.98 high173 therms/yrnatural gas or propane
Noritz NRCR92DV (GQ-C2661WXQ-FF US)
Show 2 model numbers
  • Noritz NRCR92DV (GQ-C2661WXQ-FF US), NRCR92DV (GQ-C2661WXQ-FF-1 US)
4.7 gal/min165,000 Btu/h0.98 high173 therms/yrnatural gas or propane
A. O. Smith ATO-240H 1Also listed as American, Lochinvar, Reliance, State, Takagi
Show 26 model numbers
  • A. O. Smith ATO-240H 1**, ATO-240H 1*1, ATO-240HX3-N 1**, ATO-240HX3-P 1*1, GT15-240-NO 1**, GT15-240-PO 1*1
  • American GT-240-NEH 1**, GT-240-PEH 1*1, GT-240X3-NEH 1**, GT-240X3-PEH 1*1
  • Lochinvar LTO-240H-N 1**, LTO-240H-P 1*1, LTO-240X3-N 1**, LTO-240X3-P 1*1
  • Reliance TS-240-GEH 1**, TS-240-LEH 1*1, TS-240X3-GEH 1**, TS-240X3-LEH 1*1
  • State GTS-240-NEH 1**, GTS-240-PEH 1*1, GTS-240X3-NEH 1**, GTS-240X3-PEH 1*1
  • Takagi T-H3J-OS-N 1**, T-H3J-OS-P 1*1, TK-240X3-NEH 1**, TK-240X3-PEH 1*1
4.7 gal/min160,000 Btu/h0.95 high178 therms/yrnatural gas or propane
Rinnai (CX160I) REU-NB2530FFC-US
Show 4 model numbers
  • Rinnai (CX160I) REU-NB2530FFC-US, (CXP160I) REU-NBP2530FFC-US, (RX160I) REU-NB2530FF-US, (RXP160I) REU-NBP2530FF-US
4.6 gal/min160,000 Btu/h0.97 high175 therms/yrnatural gas or propane
Bosch T9800 SE 160Also listed as Bradford White
Show 5 model numbers
  • Bosch T9800 SE 160, T9800 SEO 160, T9900 SE 160
  • Bradford White RTG-K-160N1, RTG-K-160N2
4.6 gal/min160,000 Btu/h0.95 high178 therms/yrnatural gas or propane
Under 160,000 Btu/h11 sets
Vesta VTP-150
Show 1 model number
  • Vesta VTP-150
4.7 gal/min150,000 Btu/h0.96 high176 therms/yrnatural gas or propane
Vesta VRP-PLUS-150
Show 1 model number
  • Vesta VRP-PLUS-150
4.7 gal/min150,000 Btu/h0.95 high178 therms/yrnatural gas or propane
Rheem ECOHS160INAlso listed as Friedrich, Richmond, Ruud
Show 18 model numbers
  • Friedrich FDTGH-S84I, FDTGH-SR84I
  • Rheem ECOHS160IN, ECOHS160IP, ECOHSR160IN, ECOHSR160IP, RECTGH-S84IN, RECTGH-S84IP, RECTGH-SR84IN, RECTGH-SR84IP, RTGH-S84I, RTGH-SR84I
  • Richmond RMTGHS84IN, RMTGHS84IP, RMTGHSR84IN, RMTGHSR84IP
  • Ruud RUTGH-S84I, RUTGH-SR84I
4.6 gal/min157,000 Btu/h0.96 high176 therms/yrnatural gas or propane
Vesta VTS-150
Show 1 model number
  • Vesta VTS-150
4.6 gal/min150,000 Btu/h0.96 high176 therms/yrnatural gas or propane
Navien NPE-180S2
Show 1 model number
  • Navien NPE-180S2
4.4 gal/min150,000 Btu/h0.96 high176 therms/yrnatural gas or propane
Midea JSG40-24PCH-LP
Show 2 model numbers
  • Midea JSG40-24PCH-LP, JSG40-24PCH-NG
4.4 gal/min150,000 Btu/h0.95 high177 therms/yrnatural gas or propane
Midea MGWH150IXNN
Show 4 model numbers
  • Midea MGWH150IXNN, MGWH150IXNP, MGWH150IXPN, MGWH150IXPP
4.4 gal/min150,000 Btu/h0.95 high175 therms/yrnatural gas or propane
Bradford White RTGR150N1Also listed as Kiturami, Laars
Show 12 model numbers
  • Bradford White RTGR150N1, RTGR150X1, RTGS150N1, RTGS150X1
  • Kiturami KGWH-150JFN, KGWH-150JFP, KGWH-150JFRN, KGWH-150JFRP
  • Laars LT150NRX1, LT150NXX1, LT150PRX1, LT150PXX1
4.3 gal/min150,000 Btu/h0.98 high173 therms/yrnatural gas or propane
Navien NPE-180A2Also listed as Vesta
Show 2 model numbers
  • Navien NPE-180A2
  • Vesta VRP-150
4.3 gal/min150,000 Btu/h0.95 high178 therms/yrnatural gas or propane
A. O. Smith ATM-140M-N 1Also listed as American, Lochinvar, Reliance, State
Show 11 model numbers
  • A. O. Smith ATM-140M-N 1**, ATM-140X3-N 1**, GT15TM-140M-N 1**
  • American MTM-140M-N 1**, MTM-140X3-N 1**
  • Lochinvar LTM-140M-N 1**, LTM-140X3-N 1**
  • Reliance RTM-140M-N 1**, RTM-140X3-N 1**
  • State STM-140M-N 1**, STM-140X3-N 1**
4.1 gal/min140,000 Btu/h0.95 high178 therms/yrnatural gas only
Rinnai (RX130I) REU-NB2024FF-US
Show 1 model number
  • Rinnai (RX130I) REU-NB2024FF-US
3.8 gal/min130,000 Btu/h0.97 medium114 therms/yrnatural gas or propane

One rating, eight brand names

35

model numbers here share every certified value of Rheem ECOHS200IN: 5.8 gal/min at a 67 °F rise, 199,000 Btu/h, UEF 0.96.

Why one rating set carries several brand names

Model numbers in that set, by brand

  • Rheem12
  • Bradford White4
  • Kiturami4
  • Laars4
  • Richmond4
  • Ruud4
  • Friedrich2
  • Navien1

By gas input

Gas inputRating setsModel numbersMax flow rangeMedian max flow
199,000 Btu/h131505.4–6.0 gal/min5.8 gal/min
170,000 to 189,000 Btu/h9855.0–5.6 gal/min5.3 gal/min
160,000 to 169,000 Btu/h7784.6–4.9 gal/min4.7 gal/min
Under 160,000 Btu/h11543.8–4.7 gal/min4.4 gal/min

Medians count each rating set once.

Fuel listing

Counted by model number. Separate natural-gas and propane versions of one heater usually carry their own model numbers.

Keep reading