Gas tankless · high draw
Noritz EZxxDV (GQ-CxxWX-FF US)
The Noritz EZxxDV (GQ-CxxWX-FF US) line holds five certified rating sets of gas tankless water heaters, 15 model numbers sold under two brand names, listed by Noritz America and Rinnai America. Gas input runs from 160,000 to 199,000 Btu/h, and max flow at a 67 °F rise runs from 4.7 to 5.6 gal/min. Noritz EZ111DV (GQ-C3261WX-FF US), the set with the most model numbers, rates 0.02 above the median UEF of the 39 high-draw gas tankless sets (0.96).
Certified as of October 27, 2026 · EPA ENERGY STAR data, public domain · Compare in the Heater finder
Size by size
| Rating set | Gas input, Btu/h | Max flow, gal/min | Share of heat ceiling | UEF | UEF rank | Therms/yr |
|---|---|---|---|---|---|---|
| Noritz EZ71DV (GQ-C2661WX-FF US)2 model numbers | 160,000 | 4.7 | 98% | 0.98 high | highest of 39, six tied | 173 |
| Noritz EZ98DV (GQ-C2860WX-FF US)1 model number | 180,000 | 5.6 | 104% | 0.96 high | eighth highest of 39, 13 tied | 176 |
| Noritz EZ98DV (GQ-C2861WX-FF US)3 model numbers | 180,000 | 5.3 | 99% | 0.98 high | highest of 39, six tied | 173 |
| Noritz EZ111DV (GQ-C3260WX-FF US)3 model numbers | 199,000 | 5.6 | 94% | 0.96 high | eighth highest of 39, 13 tied | 176 |
| Noritz EZ111DV (GQ-C3261WX-FF US)6 model numbers | 199,000 | 5.5 | 93% | 0.98 high | highest of 39, six tied | 173 |
Share of heat ceiling: listed flow ÷ the flow the gas input could heat through 67 °F at 100% efficiency; test tolerances allow a little over 100%.
Noritz EZxxDV (GQ-CxxWX-FF US): max flow against gas input
Max flow at a 67 °F rise, gal/min
Across the sizes
Moving from 160,000 Btu/h to 199,000 Btu/h of gas input lifts max flow from 4.7 gal/min to 5.6 gal/min, about 0.23 gal/min for each extra 10,000 Btu/h.
At 180,000 Btu/h the line lists two sets: EZ98DV (GQ-C2860WX-FF US) and EZ98DV (GQ-C2861WX-FF US).
Strongest placings, size by size
| Measure | Value | Median of the group | Placing | Compared with |
|---|---|---|---|---|
| UEFNoritz EZ71DV (GQ-C2661WX-FF US) | 0.98 | 0.96 | highest of 39, six tied | 39 high-draw gas tankless sets |
| Rated gas useNoritz EZ71DV (GQ-C2661WX-FF US) | 173 therms/yr | 176 therms/yr | lowest of 39, six tied | 39 high-draw gas tankless sets |
| UEFNoritz EZ98DV (GQ-C2860WX-FF US) | 0.96 | 0.96 | eighth highest of 39, 13 tied | 39 high-draw gas tankless sets |
| Max flow at a 67 °F riseNoritz EZ98DV (GQ-C2860WX-FF US) | 5.6 gal/min | 5.2 gal/min | tenth highest of 40, three tied | 40 gas tankless sets |
| UEFNoritz EZ98DV (GQ-C2861WX-FF US) | 0.98 | 0.96 | highest of 39, six tied | 39 high-draw gas tankless sets |
| Rated gas useNoritz EZ98DV (GQ-C2861WX-FF US) | 173 therms/yr | 176 therms/yr | lowest of 39, six tied | 39 high-draw gas tankless sets |
| Gas inputNoritz EZ111DV (GQ-C3260WX-FF US) | 199,000 Btu/h | 180,000 Btu/h | highest of 40, 13 tied | 40 gas tankless sets |
| UEFNoritz EZ111DV (GQ-C3260WX-FF US) | 0.96 | 0.96 | eighth highest of 39, 13 tied | 39 high-draw gas tankless sets |
| UEFNoritz EZ111DV (GQ-C3261WX-FF US) | 0.98 | 0.96 | highest of 39, six tied | 39 high-draw gas tankless sets |
| Gas inputNoritz EZ111DV (GQ-C3261WX-FF US) | 199,000 Btu/h | 180,000 Btu/h | highest of 40, 13 tied | 40 gas tankless sets |
Model numbers
The line covers 15 model numbers under two brand names, first certified 2023-02-23 and most recently 2026-02-25.
| Model number | Brand | Rating set | Vent | Fuel | Min flow | Certified |
|---|---|---|---|---|---|---|
| EZ71DV (GQ-C2661WX-FF US) | Noritz | EZ71DV (GQ-C2661WX-FF US) | Power Direct Vent | natural gas or propane | 0.40 gal/min | 2024-11-05 |
| EZ71DV (GQ-C2661WX-FF-1 US) | Noritz | EZ71DV (GQ-C2661WX-FF US) | Power Direct Vent | natural gas or propane | 0.40 gal/min | 2026-02-25 |
| EZ98DV (GQ-C2860WX-FF US) | Noritz | EZ98DV (GQ-C2860WX-FF US) | Power Direct Vent | natural gas or propane | 0.50 gal/min | 2023-02-23 |
| EZ98DV (GQ-C2861WX-FF US) | Noritz | EZ98DV (GQ-C2861WX-FF US) | Power Direct Vent | natural gas or propane | 0.40 gal/min | 2024-09-27 |
| EZ98DV (GQ-C2861WX-FF-1 US) | Noritz | EZ98DV (GQ-C2861WX-FF US) | Power Direct Vent | natural gas or propane | 0.40 gal/min | 2026-02-25 |
| (RX180I) REU-NB2934FF-US | Rinnai | EZ98DV (GQ-C2861WX-FF US) | Power Direct Vent | natural gas or propane | 0.10 gal/min | 2024-01-25 |
| EZ111DV (GQ-C3260WX-FF US) | Noritz | EZ111DV (GQ-C3260WX-FF US) | Direct Vent | natural gas or propane | 0.50 gal/min | 2023-02-23 |
| NCC199CDV (GQ-C3260WZ-FF US) | Noritz | EZ111DV (GQ-C3260WX-FF US) | Power Direct Vent | natural gas or propane | 0.50 gal/min | 2023-02-23 |
| NRCR111DV (GQ-C3260WXQ-FF US) | Noritz | EZ111DV (GQ-C3260WX-FF US) | Power Direct Vent | natural gas or propane | 0.50 gal/min | 2023-02-23 |
| EZ111DV (GQ-C3261WX-FF US) | Noritz | EZ111DV (GQ-C3261WX-FF US) | Power Direct Vent | natural gas or propane | 0.40 gal/min | 2024-11-05 |
| EZ111DV (GQ-C3261WX-FF-1 US) | Noritz | EZ111DV (GQ-C3261WX-FF US) | Power Direct Vent | natural gas or propane | 0.40 gal/min | 2026-02-25 |
| NCC199CDV (GQ-C3261WZ-FF US) | Noritz | EZ111DV (GQ-C3261WX-FF US) | Power Direct Vent | natural gas or propane | 0.40 gal/min | 2024-09-30 |
| NCC199CDV (GQ-C3261WZ-FF-1 US) | Noritz | EZ111DV (GQ-C3261WX-FF US) | Power Direct Vent | natural gas or propane | 0.40 gal/min | 2026-02-25 |
| NRCR111DV (GQ-C3261WXQ-FF US) | Noritz | EZ111DV (GQ-C3261WX-FF US) | Power Direct Vent | natural gas or propane | 0.40 gal/min | 2024-11-05 |
| NRCR111DV(GQ-C3261WXQ-FF-1 US) | Noritz | EZ111DV (GQ-C3261WX-FF US) | Power Direct Vent | natural gas or propane | 0.40 gal/min | 2026-02-25 |
Nearest certified alternatives
| Rating set | Max flow | UEF | Gas input |
|---|---|---|---|
| Rinnai (CX199I) REU-NB3237FFC-UScompared with Noritz EZ111DV (GQ-C3261WX-FF US) | +0.3 gal/min | ±0.00 | same Btu/h |
| Noritz NRCR92DV (GQ-C2661WXQ-FF US)compared with Noritz EZ111DV (GQ-C3261WX-FF US) | −0.8 gal/min | ±0.00 | −34,000 Btu/h |
| Kepler JSG52-32PCH/199KNPcompared with Noritz EZ111DV (GQ-C3260WX-FF US) | +0.1 gal/min | ±0.00 | same Btu/h |
| Rheem ECOHS200INcompared with Noritz EZ111DV (GQ-C3260WX-FF US) | +0.2 gal/min | ±0.00 | same Btu/h |
| Navien NPE-210S2compared with Noritz EZ111DV (GQ-C3260WX-FF US) | −0.3 gal/min | ±0.00 | −19,000 Btu/h |