Vesta model numbers form five certified rating sets of gas tankless water heaters across several model series, 6 model numbers sold as Vesta, listed by Vesta.DS. Gas input runs from 150,000 to 199,000 Btu/h, and max flow at a 67 °F rise runs from 4.6 to 6.0 gal/min. Vesta VTP-199 lists 6.0 gal/min, the highest of the 40 gas tankless sets (shared by two sets). Vesta VRS PLUS-199 sits exactly on the median UEF of the 39 high-draw gas tankless sets, 0.96.

Certified as of October 27, 2026 · EPA ENERGY STAR data, public domain · Compare in the Heater finder

Size by size

Certified values of Vesta gas tankless heaters
Rating setGas input, Btu/hMax flow, gal/minShare of heat ceilingUEFUEF rankTherms/yr
Vesta VRP-PLUS-1501 model number150,0004.7105%0.95 highlowest of 39, 19 tied178
Vesta VTP-1501 model number150,0004.7105%0.96 higheighth highest of 39, 13 tied176
Vesta VTS-1501 model number150,0004.6103%0.96 higheighth highest of 39, 13 tied176
Vesta VRS PLUS-1992 model numbers199,0005.999%0.96 higheighth highest of 39, 13 tied176
Vesta VTP-1991 model number199,0006.0101%0.96 higheighth highest of 39, 13 tied176

Share of heat ceiling: listed flow ÷ the flow the gas input could heat through 67 °F at 100% efficiency; test tolerances allow a little over 100%.

Vesta gas tankless heaters: max flow against gas input

Vesta gas tankless heatersOther gas tankless sets

Max flow at a 67 °F rise, gal/min

Vesta gas tankless heaters: max flow against gas input3.54.04.55.05.56.06.5120130140150160170180190200Gas input, thousand Btu/hA. O. Smith ACT-199O-N 1A. O. Smith ATHR-160M 1A. O. Smith ATHR-180M 1A. O. Smith ATHR-199M 1A. O. Smith ATI-340H 1A. O. Smith ATM-140M-N 1A. O. Smith ATM-199M-N 1A. O. Smith ATO-240H 1Bosch T9800 SE 160Bosch T9800 SE 199Bradford White RTGR150N1Kepler JSG48-29PCH/180KKepler JSG52-32PCH/199KNPMidea JSG40-24PCH-LPMidea JSG48-29PCH-LPMidea JSG52-32PCH-LPMidea MGWH150IXNNNavien NPE-180A2Navien NPE-180S2Navien NPE-210A2Navien NPE-210S2Navien NPE-240A2Noritz EZ111DV (GQ-C3260WX-FF US)Noritz EZ111DV (GQ-C3261WX-FF US)Noritz EZ71DV (GQ-C2661WX-FF US)Noritz EZ98DV (GQ-C2860WX-FF US)Noritz EZ98DV (GQ-C2861WX-FF US)Noritz NRCR92DV (GQ-C2660WXQ-FF US)Noritz NRCR92DV (GQ-C2661WXQ-FF US)Rheem ECOHS160INRheem ECOHS180INRheem ECOHS200INRinnai (CX160I) REU-NB2530FFC-USRinnai (CX199I) REU-NB3237FFC-USRinnai (RX130I) REU-NB2024FF-USVesta VRS PLUS-199Vesta VRP-PLUS-150Vesta VTP-150Vesta VTS-150Vesta VTP-199
Vesta gas tankless heaters: max flow against gas input3.54.04.55.05.56.06.5120140160180200Gas input, thousand Btu/hA. O. Smith ACT-199O-N 1A. O. Smith ATHR-160M 1A. O. Smith ATHR-180M 1A. O. Smith ATHR-199M 1A. O. Smith ATI-340H 1A. O. Smith ATM-140M-N 1A. O. Smith ATM-199M-N 1A. O. Smith ATO-240H 1Bosch T9800 SE 160Bosch T9800 SE 199Bradford White RTGR150N1Kepler JSG48-29PCH/180KKepler JSG52-32PCH/199KNPMidea JSG40-24PCH-LPMidea JSG48-29PCH-LPMidea JSG52-32PCH-LPMidea MGWH150IXNNNavien NPE-180A2Navien NPE-180S2Navien NPE-210A2Navien NPE-210S2Navien NPE-240A2Noritz EZ111DV (GQ-C3260WX-FF US)Noritz EZ111DV (GQ-C3261WX-FF US)Noritz EZ71DV (GQ-C2661WX-FF US)Noritz EZ98DV (GQ-C2860WX-FF US)Noritz EZ98DV (GQ-C2861WX-FF US)Noritz NRCR92DV (GQ-C2660WXQ-FF US)Noritz NRCR92DV (GQ-C2661WXQ-FF US)Rheem ECOHS160INRheem ECOHS180INRheem ECOHS200INRinnai (CX160I) REU-NB2530FFC-USRinnai (CX199I) REU-NB3237FFC-USRinnai (RX130I) REU-NB2024FF-USVesta VRS PLUS-199Vesta VRP-PLUS-150Vesta VTP-150Vesta VTS-150Vesta VTP-199
Filled: the five sets of Vesta gas tankless heaters; open circles: the other 35 gas tankless sets. Dashed line: the flow that the full gas input could heat through a 67 °F rise.

Across the sizes

Moving from 150,000 Btu/h to 199,000 Btu/h of gas input lifts max flow from 4.7 gal/min to 5.9 gal/min, about 0.24 gal/min for each extra 10,000 Btu/h.

At 150,000 Btu/h the line lists three sets: VRP-PLUS-150, VTP-150 and VTS-150.

Strongest placings, size by size

MeasureValueMedian of the groupPlacingCompared with
UEFVesta VRP-PLUS-1500.950.96lowest of 39, 19 tied39 high-draw gas tankless sets
Rated gas useVesta VRP-PLUS-150178 therms/yr176 therms/yrhighest of 39, 15 tied39 high-draw gas tankless sets
Gas inputVesta VTP-150150,000 Btu/h180,000 Btu/hthird lowest of 40, eight tied40 gas tankless sets
UEFVesta VTP-1500.960.96eighth highest of 39, 13 tied39 high-draw gas tankless sets
Gas inputVesta VTS-150150,000 Btu/h180,000 Btu/hthird lowest of 40, eight tied40 gas tankless sets
UEFVesta VTS-1500.960.96eighth highest of 39, 13 tied39 high-draw gas tankless sets
Gas inputVesta VRS PLUS-199199,000 Btu/h180,000 Btu/hhighest of 40, 13 tied40 gas tankless sets
Max flow at a 67 °F riseVesta VRS PLUS-1995.9 gal/min5.2 gal/minthird highest of 40, two tied40 gas tankless sets
Gas inputVesta VTP-199199,000 Btu/h180,000 Btu/hhighest of 40, 13 tied40 gas tankless sets
Max flow at a 67 °F riseVesta VTP-1996.0 gal/min5.2 gal/minhighest of 40, two tied40 gas tankless sets

Model numbers

The line covers 6 model numbers, first certified 2024-03-01 and most recently 2025-12-12.

Model numberBrandRating setVentFuelMin flowCertified
VRP-PLUS-150VestaVRP-PLUS-150Direct Ventnatural gas or propane0.50 gal/min2024-03-01
VTP-150VestaVTP-150Direct Ventnatural gas or propane0.50 gal/min2025-12-12
VTS-150VestaVTS-150Direct Ventnatural gas or propane0.50 gal/min2025-12-12
VRS PLUS-199VestaVRS PLUS-199not listednatural gas or propane0.50 gal/min2024-03-01
VTS-199VestaVRS PLUS-199Direct Ventnatural gas or propane0.50 gal/min2025-12-12
VTP-199VestaVTP-199Direct Ventnatural gas or propane0.50 gal/min2025-12-12

Nearest certified alternatives

Rating setMax flowUEFGas input
Rheem ECOHS200INcompared with Vesta VRS PLUS-199−0.1 gal/min±0.00same Btu/h
Kepler JSG52-32PCH/199KNPcompared with Vesta VRS PLUS-199−0.2 gal/min±0.00same Btu/h
Noritz EZ111DV (GQ-C3260WX-FF US)compared with Vesta VRS PLUS-199−0.3 gal/min±0.00same Btu/h
A. O. Smith ATO-240H 1compared with Vesta VRP-PLUS-150±0.0 gal/min±0.00+10,000 Btu/h
A. O. Smith ATHR-160M 1compared with Vesta VRP-PLUS-150+0.1 gal/min±0.00+10,000 Btu/h

Keep reading